Showing results: 466 - 480 of 651 items found.
-
Model 2180 -
Magnetic Instrumentation Inc.
The unit is compact and lightweight. The basic system is 7″ wide by 2.5″ high and 12″ long. When measurements are needed below approximately 100 micro-ohm-centimeters, the basic system is piggybacked onto a second enclosure that houses a power amplifier with a current gain of ten. The combined unit measures 7″ wide by 5″ high and 12″ long. The combined unit weighs 11.5 pounds. Two short cables interconnect the two enclosures for powering the power amplifier and routing the signals to the fixture or four point probe. The front panel of the basic system includes a 32-character backlit LCD display and a set of function keys. An easy-to-use menu will allow access to user defined parameters such as sample thickness, sample volume, and calibration constants; upper and lower alarm limits, relative measurements, and several others.
-
Analog Devices Inc.
Recognized as the pioneer and leader in RF detectors, Analog Devices offers a broad portfolio of high performance logarithmic amplifiers and TruPwr™ rms detectors. ADI logarithmic amplifiers measure signals up to 100 dB dynamic range, from dc to microwave, and accuracies of ±0.2 dB, and are well-suited for both RSSI and transmit power level detection. The TruPwr rms detectors address the challenge of measuring complex waveforms found in spread spectrum CDMA/W-CDMA and higher order QAM modulation systems and provide an accurately scaled dc voltage, which is the rms equivalent of the input waveform.
-
Analog Devices Inc.
Recognized as the pioneer and leader in RF detectors, Analog Devices offers a broad portfolio of high performance logarithmic amplifiers and TruPwr™ rms responding detectors. ADI logarithmic amplifiers measure signals up to 100 dB dynamic range, from dc to microwave, and accuracies of ±0.2 dB, and are well-suited for both RSSI and transmit power level detection. The TruPwr rms detectors address the challenge of measuring complex waveforms found in spread spectrum CDMA/W-CDMA and higher order QAM modulation systems and provide an accurately scaled dc voltage, which is the rms equivalent of the input waveform.
-
BBA130 -
Rohde & Schwarz GmbH & Co. KG
The R&SBBA130 broadband amplifiers offer a variety of setting options so you can optimally tune the output signal to your specific application. During operation, you can adjust the operating class for transistors between Class A and Class AB as well as choose between maximum output power or higher mismatch tolerance at the output.
-
SA801H -
Hangzhou Softel Optic Co., Ltd.
SA801H indoor unidirectional user’s amplifier is special designed for the last “1km” of the CATV bidirectional transmission network. It adopts CATV dedicated RF modules (SOT-115 packaged), has good indexes, low power consumption, high reliability and excellent cost performance. It is suitable for the small and medium sized CATV transmission network.
-
Berkeley Nucleonics Corporation
is a bin and power supply combination for plug-in modules. It can house twelve single-width modular instruments or a mixture of other sizes equivalent to twelve singles. Units that can be installed include BNC's modular digital delay generators, trigger pulse amplifiers, pulse generators, programming interfaces and the instruments of other companies that are designed to NIM standards.
-
Columbia Research Laboratories
Columbia's Integrated Accelerometers are completely self-contained vibration measuring systems having a built-in amplifier within the housing. Low output impedance allows operation directly into standard readout equipment without auxiliary signal conditioning. This type of accelerometer must be powered by a constant current power supply like Columbia's model 5421.
-
Keysight Technologies
Keysight PXI source/measure unit (SMU) offers high-throughput and measurement quality for design validation and production test of RF power amplifiers. It delivers industry-leading output stability under extreme, dynamic load conditions and unmatched transient performance to dramatically reduce voltage droop due to pulse loading for faster test time.
-
Analog Devices Inc.
The AD8452 combines a precision analog front-end controller and switch mode power supply (SMPS), pulse-width modulator (PWM) driver into a single silicon platform for high volume battery testing and formation manufacturing. A precision instrumentation amplifier (in-amp) measures the battery charge/discharge current to better than ±0.1% accuracy, while an equally accurate difference amplifier measures the battery voltage. Internal laser trimmed resistor networks establish the in-amp and difference amplifier gains (66 V/V and 0.4 V/V, respectively), and stabilize the AD8452 performance across the rated operating temperature range.
-
Insight Product Company
Insight Product Company offers IMPATT diodes with pulse power up to 20 Watt and operational frequency range up to 140 GHz. Silicon p+-p-n-n+ IMPATT diodes are designed to be used in the millimeter wave oscillators and amplifiers. They are fabricated in the metal-ruby packages with hard-lead carrier (diameter 3.0 mm, 1.5 mm).
-
Insight Product Company
Insight Product Company offers IMPATT diodes with CW power up to 400 mW and operational frequency range up to 140 GHz. Silicon p+-p-n-n+ IMPATT diodes are designed to be used in the millimeter wave oscillators and amplifiers. They are fabricated in the metal-ruby packages with hard-lead carrier (diameter 3.0 mm, 1.5 mm).
-
Teledyne RF & Microwave
This Low Noise Triple Band Voltage Controlled Oscillator was designed to meet a specific customer requirement. The VCO cover the 3300 to 4700 MHz frequency range in three bands. The output power is +9 to +12 dBm with an integrated buffer amplifier to minimize load pulling. The three bands are selected using standard TTL control.
-
Computer Conversions Corporation
The Computer Conversions Corporation POA90-3 is a programmable quadrature oscillator with a built-in power amplifier, capable of driving current loads of up to 200mA. The sinusoidal outputs are 2.5Vrms signals that are phased 90° apart as REF out and REF out +90 (Quadrature), allowing the unit to be used with Synchro, Resolver, LVDT/RVDT, Inductosyn, or similar inductive transducers.
-
6410 -
Tabor Electronics Ltd.
The PXE6410 is a PXIe based 6 based slot Gen 3 x4 chassis, that supports the Tabor Proteus Family of AWG’s and the TE330x family of PXIe RF amplifiers. The Chassis allows you to purchase any Proteus PXIe module and later add or up-grade to more channels, higher sample rates or higher output power.
-
Analog Devices Inc.
Analog Devices’ power monitoring amplifiers provide an integrated solution for digital current and voltage measurement via an on-chip, 12-bit analog-to-digital converter (ADC), communicated through an I2C interface. Leveraging ADI’s precision analog design techniques, ADI’s products are twice as precise as competing devices, offering best-in-class accuracy (<±0.8%). The power monitors complete the industry’s only monitor and sequencer family to deliver <±1% accuracy for 2 to 12 supplies.